Table 3-9.  Magnetic Field Strength and Duration Recommendations
Table 3-10.  Cure Times for Different Quantities of Catalyst.

TM-1-1500-335-23 Nondestructive Inspection Methods Manual
Page Navigation
  284    285    286    287    288  289  290    291    292    293    294  
T.O. 33B-1-1 3-120 Figure 3-77.  Typical Use of Gaussmeter Probes. h.     Adjust the magnetic field strength. (1) Electromagnets.  The magnetic field strength is adjusted to the recommended value from Table 3-10 by adjusting the control knob of the magnetization power supply.  The control knob reading and the position of magnet and pole pieces are noted so that these settings can be repeated when final magnetization is performed after addition of the rubber formulation.